Multi-Channel Anemometer – Model 1550 & 1560
Kanomax Multi-Channel Anemometers are research-grade airflow measuring instruments designed for high performance and precision. When coupled with our highly accurate probes this four-channel anemometer provides highly accurate and reliable data readings. It features a LCD display that displays the data from each channel. The Our 1550 & 1560 models house module bays for the connection of up to 24 channels (model 1560) or 64 channels (model 1550) of simultaneous air velocity measurements. Each bay accepts one of five unique modules allowing for a wide variety of custom configurations for air velocity, temperature, and humidity measurement. For a larger system, you can connect up to 5 units in a cascade for up to 320 air velocity channels and transfer the data to your company computer.
Description
Kanomax Multi-Channel Anemometers are research-grade airflow measuring instruments designed for high performance and precision. When coupled with our highly accurate probes this four-channel anemometer provides highly accurate and reliable data readings. It features a LCD display that displays the data from each channel. The Our 1550 & 1560 models house module bays for the connection of up to 24 channels (model 1560) or 64 channels (model 1550) of simultaneous air velocity measurements. Each bay accepts one of five unique modules allowing for a wide variety of custom configurations for air velocity, temperature, and humidity measurement. For a larger system, you can connect up to 5 units in a cascade for up to 320 air velocity channels and transfer the data to your company computer.
| Main Unit Specifications | ||
|---|---|---|
| Model | 1550 | 1560 |
| Display Resolution | 0.01 m/s (@ range of 0 to 9.99m/s) 0.1 m/s (@ 10 m/s or more) 0.1°C (Temperature) 0.1% (Relative Humidity) |
|
| Number of Module Slots | 16 | 6 |
| Analog Output | 0 to 5 V (with optional module) | |
| Interface | RS-232C | |
| Operation Temperature | 41 to 104°F (5 to 40°C) with no condensation | |
| Storage Temperature Range | 14 to 122°F (-10 to 50°C) with no condensation | |
| Dimensions | 16.9″ x 19.6″ x 5.5″ (430 x 500 x 140 mm) | 8.9″ x 12.8″ x 5.5″ (226 x 325 x 140mm) |
| Weight | 22lbs (10kg) | 11lbs (5kg) |
| Power | AC 100V (50/60 Hz) | |
| Warranty | 1 year | |
| Standard Accessory | Meter, Operation Manual, RS-232C Cable, Power Cord, Fuse | |
| Optional Probe Specifications | |
|---|---|
| Air Velocity | |
| Ranges | 0.1 to 25.0 m/s 0.1 to 50.0 m/s |
| Accuracy | +/- (3% of READING +/- 0.1) m/s |
| Operating Temperature Range | -4 to 158°F (-20 to 70°C) with no condensation |
| Storage Temperature Range | 14 to 122°F (-10 to 50°C) with no condensation |
| Warranty | 1 year |
| Standard Accessory | Probe, Data ROM, NIST Certificate |
| Model | 0962-00 | 0963-00 | 0965-00 | 0965-01 | 0965-03 | 0965-04 | 0965-07 | 0965-08 | 0965-09 | 0965-10 |
|---|---|---|---|---|---|---|---|---|---|---|
| Air Velocity Range (m/s) | 0.1 to 50.0 | 0.1 to 50.0 | 0.1 to 25.0 | 0.1 to 25.0 | 0.1 to 25.0 | 0.1 to 25.0 | 0.1 to 25.0 | 0.1 to 25.0 | 0.1 to 50.0 | 0.1 to 50.0 |
| Airflow Directivity | Mono | Mono | Omni | Omni | Omni | Omni | Omni | Omni | Omni | Omni |
| Probe Type | Rod | Rod | Spherical | Spherical | Miniature | Miniature | Miniature | Miniature | Spherical | Spherical |
| Air Velocity | O | O | O | O | O | O | O | O | O | O |
| Acclimation Time (sec) | 1 | 1 | 7 | 7 | 7 | 7 | 7 | 7 | 7 | 7 |
Air and Temperature Probe Specifications
| Air Velocity | |
|---|---|
| Ranges | 0.1 to 25.0 m/s 0.1 to 50.0 m/s |
| Accuracy | +/- (3% of READING +/- 0.1) m/s |
| Temperature | |
| Ranges | 0 to 100 °C |
| Accuracy | +/- 1 °C |
| Operating Temperature Range | -4 to 158°F (-20 to 70°C) with no condensation |
| Storage Temperature Range | 14 to 122°F (-10 to 50°C) with no condensation |
| Warranty | 1 year |
| Standard Accessory | Probe, Data ROM, NIST Certificate |
| Model | 0962-21 | 0963-21 | 0965-21 |
|---|---|---|---|
| Air Velocity Range (m/s) | 0.1 to 50.0 | 0.1 to 50.0 | 0.1 to 25.0 |
| Airflow Directivity | Mono | Mono | Omni |
| Probe Type | Rod | Rod | Spherical |
| Air Velocity | O | O | O |
| Air Temperature | O | O | O |
| Acclimation time (sec) | 1 | 1 | 7 |
Air, Temperature, and Relative Humidity Probe Specifications
| Air Velocity | |
|---|---|
| Ranges | 0.1 to 25.0 m/s 0.1 to 50.0 m/s |
| Accuracy | +/- (3% of READING +/- 0.1) m/s |
| Temperature | |
| Ranges | 0 to 60 °C |
| Accuracy | +/- 1 °C |
| Relative Humidity | |
| Ranges | 5 to 95 %RH |
| Accuracy | +/- 3% (@ 5 to 80%RH) +/- 5% (@ 80 to 95 %RH) |
| Operating Temperature Range | -4 to 158°F (-20 to 70°C) with no condensation |
| Storage Temperature Range | 14 to 122°F (-10 to 50°C) with no condensation |
| Warranty | 1 year |
| Standard Accessory | Probe, Data ROM, NIST Certificate |
| Model | 0963-31 | 0965-31 |
|---|---|---|
| Air Velocity Range (m/s) | 0.1 to 50.0 | 0.1 to 25.0 |
| Airflow Directivity | Mono | Omni |
| Probe Type | Rod | Spherical |
| Air Velocity | O | O |
| Air Temperature | O | O |
| Relative Humidity | O | O |
| Acclimation time (sec) | 1 | 7 |
Additional information
| Number of Module Slots | 16, 6 |
|---|



Reviews
There are no reviews yet.