Rotating Vane Anemometer – 6810 Series
The Anemomaster Rotating Vane 6810 Series of anemometers offers a range of highly accurate airflow measuring devices. Models include industrial grade enclosure and probe. They automatically calculate volume flow in CFM (cubic feet per minute) or CMH (cubic meters per hour). When measuring ducts dimensions are stored in memory on turn-off and do not need to be re-entered. These vane anemomters can store up to 10 different commonly-used duct sizes for quick, convenient readings in the field. Models also available for airflow/temperature and airflow/termperature/humidity.
Description
The Anemomaster Rotating Vane 6810 Series of anemometers offers a range of highly accurate airflow measuring devices. Models include industrial grade enclosure and probe. They automatically calculate volume flow in CFM (cubic feet per minute) or CMH (cubic meters per hour). When measuring ducts dimensions are stored in memory on turn-off and do not need to be re-entered. These vane anemomters can store up to 10 different commonly-used duct sizes for quick, convenient readings in the field. Models also available for airflow/temperature and airflow/termperature/humidity.
Main Unit Specifications:
| Air Velocity | Range | 1″ Probe: 300 to 6890 FPM (1.5 to 35 m/s) 2.75″ Probe: 50 to 7800 FPM (0.2 to 40 m/s) |
| Accuracy | 1″Probe: ±0.5% of Full-scale + 0.75% of READING ±1 digit 2.75″Probe :±1.0% of READING ±1 digit |
|
| Resolution | 1 FPM or 0.01 m/s |
| Temperature
(6813 & 6815) |
Range | APT (VANE TEMP): -4 to 212˚F (-20 to 100˚C) HTP202 TEMP Probe: -4 to 176˚F (-20 to 80˚C) |
| Accuracy | ± (0.3°C + 0.2% of READING in °C) | |
| Resolution | 0.1 ˚F or 0.1℃ |
|
Humidity (6815) |
Range | 5.0 to 95.0 %RH |
| Accuracy | ± 2.0 %RH | |
| Resolution | 0.1 %RH |
| Additional Specifications | |||
|---|---|---|---|
| Vane Model Support | 6812 | 6813 | 6815 |
| AP275(2.75″ Vane) or AP100(1.00″ Vane) |
O | N/A | O |
| APT275 (2.75″ Vane) or APT100 (1.00″ Vane )Temperature on Vane |
N/A | O | N/A |
| Relative Humidity (RH)/ Temperature Probe |
N/A | N/A | O |
| Optional Outputs | 6812 | 6813 | 6815 |
| USB Communication | Option (10216) | Option (10223) | |
| RS232 Communication | Option (10217) | Option (10224) | |
| Analog 0 to 5 Volt Output | Option (10215) | Option (10222) | |
| Analog & RS232 | Option (10219) | Option (10224) | |
| Analog & USB | Option (10218) | Option (10225) | |
| Accessories | 6812 | 6813 | 6815 |
| Protective Boot (10227) | Option | Option | Option |
| Cables (various lengths) | See “Accessories” Section for part numbers | ||
Additional information
| Vane Model Support: | 6812, 6813, 6815, 6812-S, 6813-S, 6815-S |
|---|