{"id":88252,"date":"2020-05-12T10:42:14","date_gmt":"2020-05-12T15:42:14","guid":{"rendered":"http:\/\/unioninst.com\/?post_type=product&#038;p=88252"},"modified":"2021-06-25T16:19:32","modified_gmt":"2021-06-25T21:19:32","slug":"traceable-logger-trac-rh-temperature-datalogger","status":"publish","type":"product","link":"https:\/\/unioninst.com\/?product=traceable-logger-trac-rh-temperature-datalogger","title":{"rendered":"Traceable\u00ae Logger-Trac\u2122 RH\/Temperature Datalogger"},"content":{"rendered":"<h3><span style=\"color: #000000;\"><strong>FEATURES:<\/strong><\/span><\/h3>\n<ul>\n<li><span style=\"color: #000000;\">Alarm set points (temperature only)<\/span><\/li>\n<li><span style=\"color: #000000;\">Recording interval (temperature\/humidity)<\/span><\/li>\n<li><span style=\"color: #000000;\">Start delay<\/span><\/li>\n<li><span style=\"color: #000000;\">Unit description<\/span><\/li>\n<li><span style=\"color: #000000;\">User may set Time zone<\/span><\/li>\n<li><span style=\"color: #000000;\">Temperature unit of measure<\/span><\/li>\n<li><span style=\"color: #000000;\">Stop key enable<\/span><\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<h3><span style=\"color: #000000;\"><strong>IMMEDIATELY KNOW THE TEMPERATURE AND HUMIDITY EXCURSION DURATION<\/strong><\/span><\/h3>\n<p><span style=\"color: #000000;\">Active LCD display technology allows the duration (cumulative time) for the temperature excursion to be viewed on the display immediately without the need to download data.\u00a0 The user may select the acceptable humidity and temperature parameters (high and low values) in 1% or 1\u00b0 increments. \u00a0The cumulative alarm duration timer is started each time the humidity and\/or temperature reading is outside an acceptable parameters providing a total excursion time since the start of recording.<\/span><\/p>\n<p>&nbsp;<\/p>\n<h3><span style=\"color: #000000;\"><strong>ALARM TALLY AND USER SELECTABLE NOTIFICATION<\/strong><\/span><\/h3>\n<p><span style=\"color: #000000;\">LCD shows the running alarm tally based on the acceptable humidity\/temperature range and recording interval.\u00a0\u00a0 Alarm tally is incremented, when readings move outside parameters during the recording interval.<\/span><\/p>\n<p>&nbsp;<\/p>\n<h3><span style=\"color: #000000;\"><strong>USER SELECTABLE RECORDING INTERVALS<\/strong><\/span><\/h3>\n<p><span style=\"color: #000000;\">For complete flexibility, the user-defined recording interval may be set based on the number of desired days to log (from 4 hours to 365 days) or the desired time interval (from every 2 seconds to every 24 hours).\u00a0 Internal flash memory stores 7680 readings.\u00a0 To insure that no data is lost, once the memory is full the thermometer\/hygrometer will stop logging data (data will not be overwritten).\u00a0 While recording, the following information is displayed:\u00a0 Current relative humidity and temperature, Min\/Max temperature achieved, cumulative running time.\u00a0 Once an alarm condition has occurred, the following additional information is displayed: Alarm Tally, \u201cALARM\u201d notification, cumulative alarm time.<\/span><\/p>\n<p>&nbsp;<\/p>\n<h3><span style=\"color: #000000;\"><strong>COMPACT SIZE<\/strong><\/span><\/h3>\n<p><span style=\"color: #000000;\">Measuring only 3.25 x 2 x 1.12 inches and weighing only 0.85 ounces, it is the perfect solution for monitoring material in transit as well as reagents, clinical samples, botanical environments, pharmaceuticals and food items in any location.\u00a0 Waterproof design (IP66) eliminates concerns when located in damp environments or areas that are required to be washed down.<\/span><\/p>\n<p>&nbsp;<\/p>\n<h3><span style=\"color: #000000;\"><strong>TRACEABLE TO\u00a0<a style=\"color: #000000;\" href=\"https:\/\/www.nist.gov\/about-nist\" target=\"_blank\" rel=\"noopener noreferrer\">NIST<\/a>\u00a0FOR ACCURACY<\/strong><\/span><\/h3>\n<p><span style=\"color: #000000;\">Multi-point calibration on an individually-numbered Traceable<sup>\u00ae<\/sup>\u00a0Certificate which assures accuracy from our\u00a0<a style=\"color: #000000;\" href=\"https:\/\/www.traceable.com\/media\/wysiwyg\/Technical\/5252016\/ISOIEC17025_A2LA_Accredited_Laboratory2.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">ISO\/IEC 17025:2017 (1750.01)<\/a>\u00a0calibration laboratory accredited by\u00a0<a style=\"color: #000000;\" href=\"https:\/\/www.a2la.org\/genweb\/about.cfm\" target=\"_blank\" rel=\"noopener noreferrer\">A2LA<\/a>.\u00a0 It indicates traceability of measurements to the SI units through\u00a0<a style=\"color: #000000;\" href=\"https:\/\/www.nist.gov\/about-nist\" target=\"_blank\" rel=\"noopener noreferrer\">NIST<\/a>\u00a0or other recognized national measurement institutes (<a style=\"color: #000000;\" href=\"http:\/\/www.measurement.gov.au\/Pages\/default.aspx\" target=\"_blank\" rel=\"noopener noreferrer\">NMI<\/a>) that are signatories to the CIPM Mutual Recognition Agreement.\u00a0 Individual Logger-Trac\u2122 RH\/Thermometers are pre-programmed with alarm values of 2\u00b0C (low) and 8\u00b0C (high) and a recording interval to allow for 30 days of recording (readings are logged every 5 minutes, 33 seconds).<\/span><\/p>\n<p>&nbsp;<\/p>\n<table border=\"1\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td valign=\"top\"><span style=\"color: #000000;\">Logging Duration<\/span><\/td>\n<td valign=\"top\"><span style=\"color: #000000;\">Sample Interval<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span style=\"color: #000000;\">4 days<\/span><\/td>\n<td valign=\"top\"><span style=\"color: #000000;\">11 seconds<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span style=\"color: #000000;\">7 days<\/span><\/td>\n<td valign=\"top\"><span style=\"color: #000000;\">19 seconds<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span style=\"color: #000000;\">16 days<\/span><\/td>\n<td valign=\"top\"><span style=\"color: #000000;\">43 seconds<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span style=\"color: #000000;\">30 days<\/span><\/td>\n<td valign=\"top\"><span style=\"color: #000000;\">1 minute 20 seconds<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span style=\"color: #000000;\">60 days<\/span><\/td>\n<td valign=\"top\"><span style=\"color: #000000;\">2 minutes 39 seconds<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span style=\"color: #000000;\">90 days<\/span><\/td>\n<td valign=\"top\"><span style=\"color: #000000;\">3 minutes 58 seconds<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span style=\"color: #000000;\">365 days<\/span><\/td>\n<td valign=\"top\"><span style=\"color: #000000;\">16 minutes 4 seconds<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p><span style=\"color: #000000;\">Accessory\u00a0<a style=\"color: #000000;\" href=\"http:\/\/unioninst.com\/producto\/maxithermo-software-use-with-6540-and-6550\/\" target=\"_blank\" rel=\"noopener noreferrer\">MaxiThermal\u2122 Software<\/a><\/span><\/p>\n<p><span style=\"color: #000000;\">Cable required to program these values.\u00a0 Software and cable allows for the following parameters to be set by the user:<\/span><\/p>\n<ul>\n<li><span style=\"color: #000000;\">High\/Low Alarm set points<\/span><\/li>\n<li><span style=\"color: #000000;\">Recording interval<\/span><\/li>\n<li><span style=\"color: #000000;\">Start Data-logging\/Alarm Condition delay<\/span><\/li>\n<li><span style=\"color: #000000;\">User\u2019s unit description<\/span><\/li>\n<li><span style=\"color: #000000;\">Time and Time zone<\/span><\/li>\n<li><span style=\"color: #000000;\">Temperature unit of measure (\u00b0F\/\u00b0C)<\/span><\/li>\n<li><span style=\"color: #000000;\">Stop key enable<\/span><\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<ul>\n<li><span style=\"color: #000000;\">Displays cumulative Alarm Duration from user selected Minimum\/Maximum values<\/span><\/li>\n<li><span style=\"color: #000000;\">Reusable\/Re-programmable<\/span><\/li>\n<li><span style=\"color: #000000;\">Perfect for monitoring material during transportation<\/span><\/li>\n<li><span style=\"color: #000000;\">Integrates with MaxiThermal Software (Cat. No. 6580) for complete data analysis<\/span><\/li>\n<\/ul>\n<blockquote><p><span style=\"color: #ffcc00;\"><strong><a style=\"color: #ffcc00;\" href=\"http:\/\/unioninst.com\/wp-content\/uploads\/2020\/05\/6550-INSTRUCTIONS.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">VIEW INSTRUCTIONS<\/a><\/strong><\/span><\/p><\/blockquote>\n<table id=\"product-attribute-specs-table\" class=\"data-table\">\n<tbody>\n<tr class=\"first odd\">\n<th class=\"label\"><span style=\"color: #000000;\">Temperature Unit<\/span><\/th>\n<td class=\"data last\"><span style=\"color: #000000;\">Fahrenheit<\/span><\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\"><span style=\"color: #000000;\">Ambient Temperature Range<\/span><\/th>\n<td class=\"data last\"><span style=\"color: #000000;\">-29\u00b0C to 72\u00b0C<\/span><\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\"><span style=\"color: #000000;\">Ambient Temp Resolution<\/span><\/th>\n<td class=\"data last\"><span style=\"color: #000000;\">0.1\u00b0<\/span><\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\"><span style=\"color: #000000;\">Ambient Temp Accuracy<\/span><\/th>\n<td class=\"data last\"><span style=\"color: #000000;\">\u00b10.2 [0 to 10]\u00b0C; \u00b10.5\u00b0C otherwise<\/span><\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\"><span style=\"color: #000000;\">RH Range<\/span><\/th>\n<td class=\"data last\"><span style=\"color: #000000;\">0 to 100 %RH<\/span><\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\"><span style=\"color: #000000;\">RH Accuracy<\/span><\/th>\n<td class=\"data last\"><span style=\"color: #000000;\">\u00b13 [25 to 75] %RH; \u00b15 %RH otherwise<\/span><\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\"><span style=\"color: #000000;\">RH Resolution<\/span><\/th>\n<td class=\"data last\"><span style=\"color: #000000;\">0.1 %RH<\/span><\/td>\n<\/tr>\n<tr class=\"last even\">\n<th class=\"label\"><span style=\"color: #000000;\">Dimensions<\/span><\/th>\n<td class=\"data last\"><span style=\"color: #000000;\">3.5 x 2.0 x 1.1 in.<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":92196,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[138,160,162,164,216,221,255,260],"product_tag":[],"class_list":["post-88252","product","type-product","status-publish","has-post-thumbnail","product_cat-industrial-parameters","product_cat-humidity-industrial-parameters","product_cat-dataloggers","product_cat-temperature-industrial-parameters","product_cat-brands","product_cat-traceable-products","product_cat-thermometers","product_cat-hygrometer","first","onbackorder","taxable","shipping-taxable","purchasable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/unioninst.com\/index.php?rest_route=\/wp\/v2\/product\/88252","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/unioninst.com\/index.php?rest_route=\/wp\/v2\/product"}],"about":[{"href":"https:\/\/unioninst.com\/index.php?rest_route=\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/unioninst.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=88252"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/unioninst.com\/index.php?rest_route=\/wp\/v2\/media\/92196"}],"wp:attachment":[{"href":"https:\/\/unioninst.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=88252"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/unioninst.com\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_brand&post=88252"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/unioninst.com\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_cat&post=88252"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/unioninst.com\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_tag&post=88252"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}