{"id":95837,"date":"2020-11-04T14:13:26","date_gmt":"2020-11-04T20:13:26","guid":{"rendered":"http:\/\/unioninst.com\/producto\/import-placeholder-for-176\/"},"modified":"2022-01-20T15:30:18","modified_gmt":"2022-01-20T21:30:18","slug":"oven-125-control-dry-glass","status":"publish","type":"product","link":"https:\/\/unioninst.com\/?product=oven-125-control-dry-glass","title":{"rendered":"Oven 125 Control  &#8211; dry  glass"},"content":{"rendered":"<p><span style=\"color: #000000;\">The models in the IKA Oven 125 dry series are powerful drying cabinets for temperature regulation, drying, ageing and heating tasks. Rapid heating and exact temperature regulation guarantee reproducible results in industrial laboratories, schools and universities, research, quality control or science. Thanks to its high quality insulation, the device has a very large interior of 125 l in relation to its total volume. This structure also reduces odour emissions and operating costs and ensures excellent temperature uniformity.<\/span><\/p>\n<p><span style=\"color: #000000;\">The Oven 125 control dry recirculating air drying cabinet heats up to 300 ?C. The additional temperature selection limited TWB (DIN 12880) meets the highest security requirements. Furthermore, the temperature curve can be monitored during testing independently of the safety temperature. This means that your test material is always protected.<\/span><\/p>\n<p><span style=\"color: #000000;\">The glass door allows for better monitoring of your samples.<\/span><\/p>\n<p>&nbsp;<\/p>\n<p><strong><span style=\"color: #000000;\">A well thought out interior<\/span><\/strong><br \/>\n<span style=\"color: #000000;\">The generously dimensioned interior of the Oven 125 control dry is comfortably illuminated. A practical cable bushing at the rear of the device is provided as standard for measurements in the oven or in the test material. The fan switches off automatically if the door is open. Up to 6 insertable shelves can be accommodated in the interior made of stainless steel.<\/span><\/p>\n<p><strong><span style=\"color: #000000;\">Interfaces<\/span><\/strong><br \/>\n<span style=\"color: #000000;\">The Oven 125 control dry offers an interface for an additional sensor for direct temperature regulation in the test material. Test parameters can be stored directly on a USB stick.<\/span><\/p>\n<p><strong><span style=\"color: #000000;\">Two displays<\/span><\/strong><br \/>\n<span style=\"color: #000000;\">All important process parameters are displayed clearly on two large TFT displays. The temperature profiles and individual user profiles can be entered via the intuitive user interface. The real-time clock enables convenient digital documentation and a time-delayed start.<\/span><\/p>\n<p>&nbsp;<\/p>\n<p><strong><span style=\"color: #000000;\">Scope of delivery<\/span><\/strong><\/p>\n<p><span style=\"color: #000000;\">IKA Oven 125 control &#8211; dry glass<\/span><br \/>\n<span style=\"color: #000000;\">Enhanced wire grid tray (2x)<\/span><br \/>\n<span style=\"color: #000000;\">Tilt protection (2x)<\/span><br \/>\n<span style=\"color: #000000;\">Screwdriver (for adjustment of temperature limit)<\/span><br \/>\n<span style=\"color: #000000;\">USB cable<\/span><br \/>\n<span style=\"color: #000000;\">Calibration certification<\/span><\/p>\n<p>&nbsp;<\/p>\n<p><strong><span style=\"color: #000000;\">Technical Data:<\/span><\/strong><\/p>\n<table id=\"tech_data\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr class=\"ika-flex-table-row\">\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">Heat output<\/span><\/td>\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">1500 W<\/span><\/td>\n<\/tr>\n<tr class=\"ika-flex-table-row\">\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">Working temperature<\/span><\/td>\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">room temp. +5 &#8211; 250 \u00b0C<\/span><\/td>\n<\/tr>\n<tr class=\"ika-flex-table-row\">\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">Adjustable safety circuit<\/span><\/td>\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">50 &#8211; 270 \u00b0C<\/span><\/td>\n<\/tr>\n<tr class=\"ika-flex-table-row\">\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">Adjustment and display resolution<\/span><\/td>\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">0.1 K<\/span><\/td>\n<\/tr>\n<tr class=\"ika-flex-table-row\">\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">Temperature stability (150\u00b0C, center, standard door)<\/span><\/td>\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">0.5 \u00b1K<\/span><\/td>\n<\/tr>\n<tr class=\"ika-flex-table-row\">\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">Temperature display<\/span><\/td>\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">yes<\/span><\/td>\n<\/tr>\n<tr class=\"ika-flex-table-row\">\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">Timer<\/span><\/td>\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">yes<\/span><\/td>\n<\/tr>\n<tr class=\"ika-flex-table-row\">\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">Timer display<\/span><\/td>\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">LCD<\/span><\/td>\n<\/tr>\n<tr class=\"ika-flex-table-row\">\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">Time setting range<\/span><\/td>\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">1 &#8211; 142560 min<\/span><\/td>\n<\/tr>\n<tr class=\"ika-flex-table-row\">\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">Number of trays max.<\/span><\/td>\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">6<\/span><\/td>\n<\/tr>\n<tr class=\"ika-flex-table-row\">\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">Load for one tray max.<\/span><\/td>\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">30 kg<\/span><\/td>\n<\/tr>\n<tr class=\"ika-flex-table-row\">\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">Operating area inner chamber<\/span><\/td>\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">550 x 525 x 450 mm<\/span><\/td>\n<\/tr>\n<tr class=\"ika-flex-table-row\">\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">Total volume inner chamber<\/span><\/td>\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">125 l<\/span><\/td>\n<\/tr>\n<tr class=\"ika-flex-table-row\">\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">Air outlet port diameter inside<\/span><\/td>\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">48 mm<\/span><\/td>\n<\/tr>\n<tr class=\"ika-flex-table-row\">\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">Dimensions (W x H x D)<\/span><\/td>\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">700 x 825 x 650 mm<\/span><\/td>\n<\/tr>\n<tr class=\"ika-flex-table-row\">\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">Weight<\/span><\/td>\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">89 kg<\/span><\/td>\n<\/tr>\n<tr class=\"ika-flex-table-row\">\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">Permissible ambient temperature<\/span><\/td>\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">5 &#8211; 40 \u00b0C<\/span><\/td>\n<\/tr>\n<tr class=\"ika-flex-table-row\">\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">Permissible relative humidity<\/span><\/td>\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">80 %<\/span><\/td>\n<\/tr>\n<tr class=\"ika-flex-table-row\">\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">Protection class according to DIN EN 60529<\/span><\/td>\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">IP 20<\/span><\/td>\n<\/tr>\n<tr class=\"ika-flex-table-row\">\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">RS 232 interface<\/span><\/td>\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">yes<\/span><\/td>\n<\/tr>\n<tr class=\"ika-flex-table-row\">\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">USB interface<\/span><\/td>\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">yes<\/span><\/td>\n<\/tr>\n<tr class=\"ika-flex-table-row\">\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">Voltage<\/span><\/td>\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">220 &#8211; 240\u00a0\/\u00a0115\u00a0\/\u00a0100 V<\/span><\/td>\n<\/tr>\n<tr class=\"ika-flex-table-row\">\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">Frequency<\/span><\/td>\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">50\/60 Hz<\/span><\/td>\n<\/tr>\n<tr class=\"ika-flex-table-row\">\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">Power input<\/span><\/td>\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">1600 W<\/span><\/td>\n<\/tr>\n<tr class=\"ika-flex-table-row\">\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">Power input standby<\/span><\/td>\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">2 W<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"excerpt":{"rendered":"<p><strong><span style=\"color: #000000;\">Feature:<\/span><\/strong><\/p>\n<p><span style=\"color: #000000;\">The Oven 125 control dry recirculating air drying cabinet heats up to 300 ?C. The additional temperature selection limited TWB (DIN 12880) meets the highest security requirements. Furthermore, the temperature curve can be monitored during testing independently of the safety temperature. This means that your test material is always protected.<\/span><\/p>\n<p><span style=\"color: #000000;\">See more information below.<\/span><\/p>\n","protected":false},"featured_media":95821,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[137,138,164,216,255,377,499,500,547,551],"product_tag":[299],"class_list":["post-95837","product","type-product","status-publish","has-post-thumbnail","product_cat-laboratory","product_cat-industrial-parameters","product_cat-temperature-industrial-parameters","product_cat-brands","product_cat-thermometers","product_cat-ika-works","product_cat-heating-tempering","product_cat-ovens","product_cat-systems","product_cat-ovens-temperature-industrial-parameters","product_tag-star","first","instock","taxable","shipping-taxable","purchasable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/unioninst.com\/index.php?rest_route=\/wp\/v2\/product\/95837","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/unioninst.com\/index.php?rest_route=\/wp\/v2\/product"}],"about":[{"href":"https:\/\/unioninst.com\/index.php?rest_route=\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/unioninst.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=95837"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/unioninst.com\/index.php?rest_route=\/wp\/v2\/media\/95821"}],"wp:attachment":[{"href":"https:\/\/unioninst.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=95837"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/unioninst.com\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_brand&post=95837"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/unioninst.com\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_cat&post=95837"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/unioninst.com\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_tag&post=95837"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}