{"id":95845,"date":"2020-11-04T14:13:27","date_gmt":"2020-11-04T20:13:27","guid":{"rendered":"http:\/\/unioninst.com\/producto\/import-placeholder-for-200\/"},"modified":"2022-01-20T15:35:46","modified_gmt":"2022-01-20T21:35:46","slug":"dry-block-heater-2","status":"publish","type":"product","link":"https:\/\/unioninst.com\/?product=dry-block-heater-2","title":{"rendered":"Dry Block Heater 2"},"content":{"rendered":"<p><span style=\"color: #000000;\">Digital block heater for two aluminum blocks provides precise temperature control in small vessels. Included PT-1000 temperature sensor allows temperature control directly in the sample vessel. It is used with PCR tubes, PCR strips, Greiner tubes, microplates and cuvettes. The block heater is ideal for melting and boiling point determination, enzyme reactions, incubation and activation of cultures, immunoassays, DNA denaturation, culture media tests, coagulation tests, blood-urea-nitrogen determinations and in situ hybridizations.<\/span><\/p>\n<ul>\n<li><span style=\"color: #000000;\">Stepless adjustable temperature up to 120 \u00b0C<\/span><\/li>\n<li><span style=\"color: #000000;\">Timer: Countdown, adjustable from 1 min to 99h 59min<\/span><\/li>\n<li><span style=\"color: #000000;\">Counter: Display of heating time<\/span><\/li>\n<li><span style=\"color: #000000;\">Highly versatile with a large number of blocks<\/span><\/li>\n<li><span style=\"color: #000000;\">Error code display<\/span><\/li>\n<li><span style=\"color: #000000;\">Fixed safety circuit<\/span><\/li>\n<li><span style=\"color: #000000;\">Acoustic signal at end of test<\/span><\/li>\n<\/ul>\n<p><span style=\"color: #000000;\"><b>Scope of delivery<\/b><\/span><\/p>\n<ul>\n<li><span style=\"color: #000000;\">Dry Block Heater 2<\/span><\/li>\n<li><span style=\"color: #000000;\">Block remove tool<\/span><\/li>\n<li><span style=\"color: #000000;\">PT 1000.60 Temperature sensor, stainless steel<\/span><\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<p><strong><span style=\"color: #000000;\">Technical Data:<\/span><\/strong><\/p>\n<table id=\"tech_data\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr class=\"ika-flex-table-row\">\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">Number of blocks<\/span><\/td>\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">2<\/span><\/td>\n<\/tr>\n<tr class=\"ika-flex-table-row\">\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">Heat output<\/span><\/td>\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">250 W<\/span><\/td>\n<\/tr>\n<tr class=\"ika-flex-table-row\">\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">Heating temperature range<\/span><\/td>\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">room temp. +5\u00b0 &#8211; 120 \u00b0C<\/span><\/td>\n<\/tr>\n<tr class=\"ika-flex-table-row\">\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">Temperature display<\/span><\/td>\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">yes<\/span><\/td>\n<\/tr>\n<tr class=\"ika-flex-table-row\">\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">Adjustment and display resolution<\/span><\/td>\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">1 K<\/span><\/td>\n<\/tr>\n<tr class=\"ika-flex-table-row\">\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">Connection for ext. temperature sensor<\/span><\/td>\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">CT (DIN12878)<\/span><\/td>\n<\/tr>\n<tr class=\"ika-flex-table-row\">\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">PT 1000 variation;DIN EN 60751 Kl. A<\/span><\/td>\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">\u2264 \u00b1 (0.15 +0.002xITI) K<\/span><\/td>\n<\/tr>\n<tr class=\"ika-flex-table-row\">\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">Temperature stability within the blocks at 37\u00b0C *<\/span><\/td>\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">0.2 \u00b1\u00b0C<\/span><\/td>\n<\/tr>\n<tr class=\"ika-flex-table-row\">\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">Temperature stability within the blocks at 60\u00b0C *<\/span><\/td>\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">0.4 \u00b1\u00b0C<\/span><\/td>\n<\/tr>\n<tr class=\"ika-flex-table-row\">\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">Temperature Homogenity @ 37\u00b0C *<\/span><\/td>\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">0.2 K<\/span><\/td>\n<\/tr>\n<tr class=\"ika-flex-table-row\">\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">Temperature Homogenity @ 60\u00b0C *<\/span><\/td>\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">0.4 K<\/span><\/td>\n<\/tr>\n<tr class=\"ika-flex-table-row\">\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">Heatingrate \/ Heat up time with external sensor *<\/span><\/td>\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">4.5 K\/min<\/span><\/td>\n<\/tr>\n<tr class=\"ika-flex-table-row\">\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">Set-up plate material<\/span><\/td>\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">Aluminium alloy<\/span><\/td>\n<\/tr>\n<tr class=\"ika-flex-table-row\">\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">Set-up plate dimensions<\/span><\/td>\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">96 x 152 mm<\/span><\/td>\n<\/tr>\n<tr class=\"ika-flex-table-row\">\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">Fixed safety circuit<\/span><\/td>\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">150 \u00b0C<\/span><\/td>\n<\/tr>\n<tr class=\"ika-flex-table-row\">\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">Timer<\/span><\/td>\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">yes<\/span><\/td>\n<\/tr>\n<tr class=\"ika-flex-table-row\">\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">Time setting range<\/span><\/td>\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">1 &#8211; 5999 min<\/span><\/td>\n<\/tr>\n<tr class=\"ika-flex-table-row\">\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">* Measured in IKA DBH Testingblock<\/span><\/td>\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">Refer Manual for more details<\/span><\/td>\n<\/tr>\n<tr class=\"ika-flex-table-row\">\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">Dimensions (W x H x D)<\/span><\/td>\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">151 x 73 x 304 mm<\/span><\/td>\n<\/tr>\n<tr class=\"ika-flex-table-row\">\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">Weight<\/span><\/td>\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">1.3 kg<\/span><\/td>\n<\/tr>\n<tr class=\"ika-flex-table-row\">\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">Permissible ambient temperature<\/span><\/td>\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">5 &#8211; 40 \u00b0C<\/span><\/td>\n<\/tr>\n<tr class=\"ika-flex-table-row\">\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">Permissible relative humidity<\/span><\/td>\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">80 %<\/span><\/td>\n<\/tr>\n<tr class=\"ika-flex-table-row\">\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">Protection class according to DIN EN 60529<\/span><\/td>\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">IP 21<\/span><\/td>\n<\/tr>\n<tr class=\"ika-flex-table-row\">\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">Voltage<\/span><\/td>\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">220 &#8211; 240\u00a0\/\u00a0115\u00a0\/\u00a0100 V<\/span><\/td>\n<\/tr>\n<tr class=\"ika-flex-table-row\">\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">Frequency<\/span><\/td>\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">50\/60 Hz<\/span><\/td>\n<\/tr>\n<tr class=\"ika-flex-table-row\">\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">Power input<\/span><\/td>\n<td class=\"ika-flex-table-column\"><span style=\"color: #000000;\">250 W<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"excerpt":{"rendered":"<p><strong><span style=\"color: #000000;\">Features:<\/span><\/strong><\/p>\n<p><span style=\"color: #000000;\">Digital block heater for two aluminum blocks provides precise temperature control in small vessels.<\/span><br \/>\n<span style=\"color: #000000;\">Stepless adjustable temperature up to 120 \u00b0C<\/span><br \/>\n<span style=\"color: #000000;\">Timer: Countdown, adjustable from 1 min to 99h 59min<\/span><br \/>\n<span style=\"color: #000000;\">Counter: Display of heating time<\/span><br \/>\n<span style=\"color: #000000;\">Highly versatile with a large number of blocks<\/span><br \/>\n<span style=\"color: #000000;\">Error code display<\/span><br \/>\n<span style=\"color: #000000;\">Fixed safety circuit<\/span><br \/>\n<span style=\"color: #000000;\">Acoustic signal at end of test<\/span><\/p>\n","protected":false},"featured_media":95812,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[137,138,164,216,242,377,499,502,550],"product_tag":[],"class_list":["post-95845","product","type-product","status-publish","has-post-thumbnail","product_cat-laboratory","product_cat-industrial-parameters","product_cat-temperature-industrial-parameters","product_cat-brands","product_cat-tools","product_cat-ika-works","product_cat-heating-tempering","product_cat-dry-block-heater","product_cat-block-heater","first","instock","taxable","shipping-taxable","purchasable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/unioninst.com\/index.php?rest_route=\/wp\/v2\/product\/95845","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/unioninst.com\/index.php?rest_route=\/wp\/v2\/product"}],"about":[{"href":"https:\/\/unioninst.com\/index.php?rest_route=\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/unioninst.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=95845"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/unioninst.com\/index.php?rest_route=\/wp\/v2\/media\/95812"}],"wp:attachment":[{"href":"https:\/\/unioninst.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=95845"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/unioninst.com\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_brand&post=95845"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/unioninst.com\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_cat&post=95845"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/unioninst.com\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_tag&post=95845"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}