{"id":97195,"date":"2021-07-01T09:51:14","date_gmt":"2021-07-01T14:51:14","guid":{"rendered":"https:\/\/unioninst.com\/?post_type=product&#038;p=97195"},"modified":"2021-07-01T09:51:19","modified_gmt":"2021-07-01T14:51:19","slug":"indoor-air-quality-monitor","status":"publish","type":"product","link":"https:\/\/unioninst.com\/?product=indoor-air-quality-monitor","title":{"rendered":"Indoor Air Quality Monitor"},"content":{"rendered":"<p>The Kanomax Indoor Air Quality Monitor ? Model 2212 simplifies the labor involved and eliminates the need to purchase and learn multiple instruments. It simultaneously measures multiple parameters such as: CO, CO2, Temperature, and Relative Humidity. It is capable of calculating Dew Point, Web Bulb Temperature, Absolute Humidity, Humidity Ratio and % Outside Air. Calibration is easy and can be done by the user.<\/p>\n<p>The monitor can also check CO2 levels and determine the rate of exchange, or the % of outside air, being introduced to a building per ASHRAE standard 62. It is capable of examining a building?s IAQ conditions to optimize worker productivity and features quick start-up and high accuracy in measuring CO2 and CO concentration levels in the environment.<\/p>\n<p>Main Unit Specifications<br \/>\nMeasurement Specifications<br \/>\nCO\tRange\t0 to 500PPM<br \/>\nAccuracy\t+\/-3% of reading or +\/-3PPM whichever is greater<br \/>\nResolution\t0.1PPM: 0-99PPM 1PPM: 100-500 PPM<br \/>\nCO2\tRange\t0 to 5000PPM<br \/>\nAccuracy\t+\/-3% of reading or+\/-50PPM whichever is greater<br \/>\nResolution\t1PPM<br \/>\nTemperature\tRange\t? 4 to 140F (-20 to 60C)<br \/>\nAccuracy\t+\/- 1F (+\/-0.5C)<br \/>\nResolution\t0.1F (0.1C )<br \/>\nRelative Humidity\tRange\t2 to 98%RH<br \/>\nAccuracy\t2 to 80%RH: ?2%RH, 80 to 98%RH: ?3%RH<br \/>\nResolution\t0.1%RH<br \/>\nGeneral Specifications<br \/>\nFunction\tNormal Mode\tNormal measuring (do not store and calculate the data.) relative humidity, CO, CO2, dew point, wet bulb temperature, absolute humidity and humidity ratio<br \/>\nCalculation Mode\tStore the data, and calculate the maximum, minimum and average value.<br \/>\n% OA Mode\tMeasure ventilation ratio (ask for ventilation ratio by calculating from temperature and CO2 value)<br \/>\nData Output Mode\tPerform re-calculation of stored data and output of data to PC and Printer.<br \/>\nCalibration Mode\tPerform the calibration of CO and CO2.<br \/>\nOutput\tDigital\tRS232C<br \/>\nAnalog (optional)\tDC 0 to 1V<br \/>\nPower Supply\tStandard\t6x AA Batteries<br \/>\nAnalog (optional)\tDC 0 to 1V<br \/>\nDimensions\tUnit\t3.4? x 7.4? x 1.6?<br \/>\nProbe\tLength: 12.5 inch \/ Diameter: 1.0 inch<br \/>\nWeight\t1.2lbs (500g)<br \/>\nWhat?s included\tMeter, Operation manual, AA batteries, Probe stand, Probe,<br \/>\nCalibration cap, Connection tube, Data processing software (DPS), RS-232C<br \/>\ncable, Carrying case, NIST TRACEABLE CALIBRATION certificate. Optional Serial ? USB adapter and AC adapter available.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>The Kanomax Indoor Air Quality Monitor ? Model 2212 simplifies the labor involved and eliminates the need to purchase and learn multiple instruments. It simultaneously measures multiple parameters such as: CO, CO2, Temperature, and Relative Humidity. It is capable of calculating Dew Point, Web Bulb Temperature, Absolute Humidity, Humidity Ratio and % Outside Air. Calibration is easy and can be done by the user.<\/p>\n<p>The monitor can also check CO2 levels and determine the rate of exchange, or the % of outside air, being introduced to a building per ASHRAE standard 62. It is capable of examining a building?s IAQ conditions to optimize worker productivity and features quick start-up and high accuracy in measuring CO2 and CO concentration levels in the environment.<\/p>\n","protected":false},"featured_media":97096,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[216,227,559,570,571],"product_tag":[],"class_list":["post-97195","product","type-product","status-publish","has-post-thumbnail","product_cat-brands","product_cat-kanomax","product_cat-air-flow-test","product_cat-indoor-air-quality-monitors","product_cat-handheld-iaq-monitor","first","instock","taxable","shipping-taxable","purchasable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/unioninst.com\/index.php?rest_route=\/wp\/v2\/product\/97195","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/unioninst.com\/index.php?rest_route=\/wp\/v2\/product"}],"about":[{"href":"https:\/\/unioninst.com\/index.php?rest_route=\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/unioninst.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=97195"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/unioninst.com\/index.php?rest_route=\/wp\/v2\/media\/97096"}],"wp:attachment":[{"href":"https:\/\/unioninst.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=97195"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/unioninst.com\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_brand&post=97195"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/unioninst.com\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_cat&post=97195"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/unioninst.com\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_tag&post=97195"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}